BLITZ Fire Alarm Sounder with Strobe — 105dB Audible Alarm & High-Intensity Strobe, Suitable for Outdoor Use, CE & ISO 9001 Certified

35.65

Product description

Overview

  • The BLITZ Fire Alarm Sounder with Strobe is a terminal alarm device combining an audible alarm and a visual signal during a fire event, designed to quickly alert people to evacuate. The device emits a loud sound (105dB or higher) and a fast, high-intensity flash to remind people to escape immediately, with the option to select one of three different tones (ambulance sound, fire engine sound, or police car sound) via jumpers depending on the facility's needs. It operates on a 24V DC voltage with a working current of 20-50mA, with a flash unit operational life exceeding 100,000 cycles. It features a wall-mount design and is suitable for outdoor use, with an operating temperature range of -10°C to +50°C and relative humidity up to 95% non-condensing. CE and ISO 9001 certified. Available through Al-Najma Al-Wataniyah with guaranteed quality and fast delivery across Riyadh, Dammam, and all KSA regions.

Technical Specifications

SpecificationValue
CategoryFire alarm & detection equipment — sounder with strobe (sound and light alarm)
BrandBLITZ
Operating VoltageDC 24V
Working Current20 to 50mA
Audio Alarm Level≥ 105 dB
Flash Intensity≥ 1.2 WS
Flash Period≤ 1 second
Flash Unit Life≥ 100,000 operating cycles
Operating Temperature Range-10°C to +50°C
Ambient Relative Humidity≤ 95% (non-condensing)
Sound Alarm SourceThree user-selectable tones via jumpers: I Ambulance Sound, II Fire Engine Sound, III Police Car Sound
Mounting TypeWall mount
Suitable for Outdoor UseYes
Dimensions125 x 125 x 50mm
Certified StandardsCE; ISO 9001
Key FeaturesQuick response time, piezoelectric horn, high-intensity strobe, integrated electronics, high performance at low cost, 3 user-selectable tones, wall mount type
Country of OriginChina (Made in China)

Documentation & Standards

  • The sound and light alarm device is CE and ISO 9001 certified as explicitly stated in the data sheet.
  • Additional reference standards for the Saudi market:
  • CE · ISO 9001

Industrial Applications

  • B2B Sectors — Detailed Engineering Use Case:
Sector / ApplicationEngineering Use Case Details
Commercial and administrative buildingsInstallation in corridors and stairwells to provide dual audible and visual alerting, ensuring the signal reaches hearing-impaired individuals or those in high-background-noise environments
Warehouses and storage centersCovering large spaces where audible alarm alone may not reach every corner of the warehouse; the high-intensity strobe (≥1.2 WS) provides a complementary visual signal over long distances
Industrial areas and processing plantsUse in environments with high operational noise (machinery, compressors) where combining loud sound (≥105dB) with a visual flash ensures the alert is noticed despite ambient noise
Construction sites and active projectsTemporary or permanent installation in exposed outdoor work areas, benefiting from the device's outdoor-use rating and wide operating temperature range (-10 to +50°C)
Covered parking and multi-story garagesInstalling the device thanks to its outdoor-use rating in semi-open spaces exposed to weather changes and elevated humidity levels
Oil, gas & petrochemical facilitiesProviding reliable alerting in operational environments requiring immediate evacuation response, with the option to select an alarm tone (such as fire engine sound) to distinguish it from other operational equipment sounds

Supply Information

FieldValue
Lead Time2–3 working days
CoverageRiyadh · Dammam · Jeddah · Jubail · Yanbu · All KSA
Project SupplyAvailable — contact B2B team for full fire alarm system project supply

Frequently Asked Questions

Q1: Can this device be installed outdoors?

  • Yes, the device is rated as suitable for outdoor use per the data sheet, and operates within a temperature range of -10°C to +50°C and relative humidity up to 95% non-condensing.

Q2: How can the alarm tone be changed?

  • You can choose between three different tones (ambulance sound, fire engine sound, police car sound) by reconnecting the internal jumpers, without needing any additional programming tools.

Q3: How loud is the device, and is it sufficient for large spaces?

  • The device emits sound at 105dB or higher, a high level designed to cover large commercial and industrial spaces; for larger areas, distributing multiple units as part of the alarm system's engineering design is recommended.

Q4: What operating voltage does this device require?

  • The device operates on a 24V DC voltage with a working current of 20-50mA, the standard voltage common to most fire alarm control panels.

Q5: Is delivery available to Riyadh, Dammam, and all KSA regions?

  • Yes, supply is available across all KSA regions with bulk quantities available for B2B projects.

Internal Links

_________________________________________________________________________________________

Copyright © 2026 - (Al-Najma Al-Wataniyah Est.) · All Rights Reserved · KSA

We are committed to providing the highest quality standards for our customers in the Kingdom of Saudi Arabia; approved certificates or technical data sheets are available for every product to ensure your project requirements are met.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌