BLITZ Fire Alarm Manual Call Point — Instant Manual Activation, Dual LED Indicators, CE & ISO 9001 Certified

39.10

Product description

Overview

  • The BLITZ Fire Alarm Manual Call Point is a manual activation (input) device mounted on walls at strategic points throughout a building, allowing anyone who discovers a fire to immediately activate the alarm system by pressing the button or breaking the front glass, depending on the device model. Upon activation, the device sends a signal to the central fire alarm control panel, which in turn triggers the audible and visual alarm devices throughout the building to alert occupants to evacuate. The device is available in two designs: a simple direct push-button type, and a breakable glass-front type to prevent accidental or tampered activation. The device features two LED indicators (green and red) to signal power status and activation status. It operates on a 24V DC voltage, with a low standby current not exceeding 100 µA and a contact resistance not exceeding 0.02 ohm to ensure reliable response upon activation. CE and ISO 9001 certified. Available through Al-Najma Al-Wataniyah with guaranteed quality and fast delivery across Riyadh, Dammam, and all KSA regions.

Technical Specifications

SpecificationValue
CategoryFire alarm & detection equipment — manual call point
BrandBLITZ
Working VoltageDC 24V
Standby Current≤ 100 µA
Contact Resistance≤ 0.02 ohm
Operating Temperature Range-10°C to +65°C
Ambient Relative Humidity10% to 90% (non-condensing)
Dimensions87 x 87 x 52.5mm
Activation MechanismTwo designs: direct push button, or breakable glass front to prevent accidental activation
Status IndicatorsTwo LED indicators (green for power, red for activation)
Certified StandardsCE; ISO 9001
Key FeaturesSound & light alarm indication, easy installation, reliable performance, simple operation
Country of OriginChina (Made in China)

Certificates & Standards

  • The manual call point is CE and ISO 9001 certified as explicitly stated in the data sheet.
  • Additional reference standards for the Saudi market:
  • CE · ISO 9001

Industrial Applications

  • B2B Sectors — Detailed Engineering Use Case:
Sector / ApplicationEngineering Use Case Details
Commercial and administrative buildingsInstallation at emergency exits, stairwells, and assembly points to allow any occupant discovering a fire to activate the system immediately without waiting for automatic detection
FactoriesDistributing call points along production lines and high-risk work areas, benefiting from the breakable-glass model to prevent accidental activation in busy work environments
Schools and educational facilitiesInstallation at appropriate height in corridors and near exits to enable teachers and staff to activate quickly during evacuation procedures, with operation simplicity suited to emergency situations
Hotels and hospitality facilitiesCovering corridors and stairwells in multi-story buildings to enable guests and staff to alert immediately, in line with guest safety regulatory requirements
Hospitals and healthcare facilitiesInstalling additional call points in corridors and wards where rapid manual activation by medical staff is faster than waiting for automatic detector response in critical emergencies
Warehouses and storage centersDistributing call points at regular intervals across large spaces to ensure any worker can reach a nearby activation point within seconds of discovering a fire

Supply Information

FieldValue
Lead Time2-3 working days
CoverageRiyadh · Dammam · Jeddah · Jubail · Yanbu · All KSA
Project ServiceAvailable — contact the sales team for full fire alarm system project supply

Frequently Asked Questions

Q1: What is the difference between the push-button and breakable-glass models?

  • The direct push-button model is activated with a single simple press suited to very quick activation, while the glass model requires breaking the front panel first, reducing the likelihood of accidental activation or tampering in high-traffic areas such as factories.

Q2: Does the device require periodic maintenance or replacement?

  • The data sheet does not explicitly specify a maintenance schedule; we recommend following the standard periodic testing program for fire alarm systems (typically monthly testing of a sample of call points) to confirm contact resistance remains within the specified limit (≤0.02 ohm).

Q3: What operating voltage does this device require?

  • The device operates on a 24V DC voltage, the standard voltage common to most conventional and addressable fire alarm control panels.

Q4: What do the green and red LED indicators on the device mean?

  • The green indicator typically signals power presence and circuit integrity, while the red indicator signals the device's actual activation status when pressed or when the glass is broken.

Q5: Is delivery available to Riyadh, Dammam, and all KSA regions?

  • Yes, supply is available across all KSA regions with bulk quantities available for B2B projects.