Allwear YC2121 Permanent Flame Retardant Balaclava – ARC 2, ATPV 12.0 cal/cm²

57.50

Petrol Blue
Khaki

Product description

Overview

  • The Allwear YC2121 is a permanent flame retardant balaclava that protects the head, neck and lower face of workers exposed to electric arc and flame hazards. It is made from 100% cotton at 300 GSM, a pre-shrunk fabric that stays comfortable in hot working conditions while keeping its flame-retardant performance. The ergonomic contoured fit covers the head and lower face, leaving an opening for the eyes, and a short peak at the front, while the circular drape extends over the neck and shoulders to protect the area most often left exposed between the collar and helmet. The balaclava is ARC 2 rated with an ATPV of 12.0 cal/cm², is compliant with NFPA 70E and ASTM, and carries a prominent FR label so supervisors can identify it at a glance. It is offered in one standard size that fits all, in Petrol Blue (YC-2121-PB) or Khaki (YC-2121-KH), to match FR coveralls and site colour codes.

Technical Specifications

Specification Value
Category Flame Retardant Clothing – FR Head & Neck Protection
Brand Allwear
Model Code YC2121
Description Permanent Flame Retardant Balaclava
Fabric 100% Cotton
Fabric Weight 300 GSM
Shrinkage Pre-Shrunk
Flame Retardancy Permanent Flame Retardant
Arc Rating (ATPV) 12.0 cal/cm²
Arc Rating Category ARC 2
Compliance NFPA 70E · ASTM
Coverage Head, neck and lower face, with circular neck drape
Fit Ergonomic contoured fit
Identification Prominent FR label
Colors Petrol Blue · Khaki
Color Codes YC-2121-PB (Petrol Blue) · YC-2121-KH (Khaki)
Size Standard – one size fits all
SKU ALLWEAR-YC2121

Size & Color Table

Article Code Color Size
YC-2121-PB Petrol Blue Standard – one size fits all
YC-2121-KH Khaki Standard – one size fits all

Documentation & Standards

  • The Allwear YC2121 is ARC 2 rated with an ATPV (Arc Thermal Performance Value) of 12.0 cal/cm², and is compliant with NFPA 70E and ASTM. ATPV expresses how much incident energy the fabric can block before the wearer would be likely to receive a second-degree burn, and ARC 2 places the balaclava in Arc Rating Category 2 under NFPA 70E, the standard that sets electrical safety practice in the workplace, including the protective clothing required for each level of arc-flash hazard. For the customer, this means the balaclava can be specified as the head and neck layer of an ARC 2 PPE kit for electrical work, and its permanent flame-retardant cotton gives reliable protection against brief flame exposure in industrial plants.
  • Additional reference standards for the Saudi market
  • NFPA 70E — Standard for Electrical Safety in the Workplace: defines arc-flash PPE categories, including Category 2.
  • ASTM F1506 — Performance specification for flame-resistant and arc-rated textile materials for wearing apparel used by electrical workers.
  • ASTM F1959 — Test method for determining the arc rating (ATPV) of materials for clothing.
  • NFPA 2112 and EN ISO 11612 — Related standards for flame-resistant garments protecting against flash fire and heat in industrial plants.
  • SASO technical regulation for personal protective equipment — the Saudi regulatory framework for PPE placed on the KSA market.
  • SABER — the Saudi electronic conformity platform for product and shipment certificates for goods entering the Kingdom.

Industrial Applications

  • B2B Sectors — Detailed Engineering Use Case
Sector / Application Engineering Use Case Details
Electrical Utilities & Substations Worn as the head and neck layer of an ARC 2 PPE kit during switching, racking and testing on energised equipment, under a hard hat and with an arc-rated face shield.
Industrial Electrical Maintenance For electricians working on switchgear, motor control centres and distribution panels in factories, where the circular drape protects the neck between the collar and the helmet.
Oil & Gas, Refineries & Petrochemical Plants Permanent flame-retardant cotton covers the head and neck against brief flame exposure in process areas, alongside FR coveralls.
Plant Shutdowns & Hot Work Areas Provides flame-retardant head cover for maintenance crews during turnarounds, worn under hard hats and alongside FR coveralls.
Power Generation & Desalination Plants Suits operators and maintenance staff in high-voltage areas, with 100% cotton suited to the Saudi climate and colours that match site uniforms.

Supply Information

Field Details
Lead Time 2-3 Business Days
Coverage Riyadh · Dammam · Jeddah · Jubail · Yanbu · All KSA
Project Supply Bulk and scheduled supply of FR PPE kits for company workforces, shutdowns and projects across the Kingdom

Frequently Asked Questions

Q1: What does ARC 2 rated mean?

  • ARC 2 places the balaclava in Arc Rating Category 2 under NFPA 70E. With an ATPV of 12.0 cal/cm², it can be used as the head and neck layer of PPE for tasks assessed at Category 2.

Q2: Does the balaclava protect the face from arc flash on its own?

  • The balaclava protects the head, neck and lower face. For arc-flash work, wear it with an arc-rated face shield and hard hat that match the PPE category of the task.

Q3: Will the flame-retardant protection wash out?

  • The YC2121 is permanent flame retardant, built to keep its protection through the life of the garment when washed according to its care label.

Q4: What sizes and colours are available?

  • One standard size fits all, in Petrol Blue (YC-2121-PB) or Khaki (YC-2121-KH).

Q5: Do you deliver across Saudi Arabia?

  • Yes. Al-Najma Al-Wataniyah delivers to Riyadh, Dammam, Jeddah, Jubail, Yanbu and all regions of the Kingdom, with bulk supply for companies and projects.

Internal Links

_________________________________________________________________________________________

Copyright © 2026 — (Al-Najma Al-Wataniyah Est.) — All Rights Reserved — Kingdom of Saudi Arabia

We are committed to providing the highest quality standards for our customers in the Kingdom of Saudi Arabia; we provide approved certificates or technical data sheets for each product to ensure that your project requirements are met.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌