- The BLITZ Conventional Fire Alarm Control Panel is the central hub of the entire fire alarm system, designed to offer a suitable blend of affordable design and quality with the latest technology. The series is available in six different zone-count capacities (1, 2, 4, 8, 16, and 24 zones), all equipped with a built-in backup battery, so the most suitable variant can be selected for the facility's size without overpaying for unneeded capacity. This content specifically documents the largest variant, with a capacity of 24 fixed detection zones, and the ability to connect up to 25 combined devices (smoke detectors, heat detectors, and manual call points) per zone. Specifically designed to suit small commercial buildings and small-scale industries, it is a user-friendly standalone control unit, with an optional zone-wise sounder or contact connection. The panel provides one fire relay output and one fault relay output, plus two sounder outputs, with clear LED indicators for each zone's status and the overall system state. It comes with a durable metal case and a built-in backup battery to ensure continued operation during mains power outages. CE and ISO 9001 certified. Available through Al-Najma Al-Wataniyah with guaranteed quality and fast delivery across Riyadh, Dammam, and all KSA regions.
Technical Specifications
| Specification | Value |
| Category | Fire alarm & detection equipment — conventional fire alarm control panel |
| Brand | BLITZ |
| Number of Zones | 1 to 24 fixed zones |
| Supported Device Capacity | Up to 25 combined devices (detectors + manual call points) per zone |
| Relay Outputs | 1 Fire relay output and 1 Fault relay output |
| Sounder Outputs | 2 sounder outputs |
| Mains Supply Voltage | AC 220 to 230V |
| Frequency | 50Hz / 60Hz |
| Rated Current | 130mA |
| Internal Power Supply | DC 27V nominal |
| Auxiliary Power Output | DC 27V nominal |
| Total Output Current Limit | 400mA |
| Max Source Current | 30mA |
| Dimensions | 270 x 200 x 80mm |
| Case Material | Metal case |
| Battery | Built-in backup battery with over-discharge protection |
| Control Buttons | RESET/TEST, SILENCE, EVACUATE, DISABLE, ARM CONTROLS keyswitch |
| Status Indicators | Key-on, power-on, general fault/fire, disabled, silenced, sounder alarm/fault, mains supply, battery supply, plus independent fire/fault indicators per zone |
| Certified Standards | CE; ISO 9001 |
| Key Features | Supports up to 24 fixed zones, up to 25 combined devices per zone, fire and fault relay output, 2 sounder outputs, clear LED indication, durable metal case, built-in backup battery |
| Country of Origin | China (Made in China) |
Size & Color
- Available in six different zone-count capacities, and all variants come with a built-in backup battery:
| Variant | Zones | Battery | SKU |
| Conventional Panel 1-Zone | 1 | Included | BLITZ-FACP-01Z |
| Conventional Panel 2-Zone | 2 | Included | BLITZ-FACP-02Z |
| Conventional Panel 4-Zone | 4 | Included | BLITZ-FACP-04Z |
| Conventional Panel 8-Zone | 8 | Included | BLITZ-FACP-08Z |
| Conventional Panel 16-Zone | 16 | Included | BLITZ-FACP-16Z |
| Conventional Panel 24-Zone | 24 | Included | BLITZ-FACP-24Z |
Documentation & Standards
- The panel is CE and ISO 9001 certified, as explicitly stated in the data sheet.
- Additional reference standards for the Saudi market:
- CE · ISO 9001
Industrial Applications
- B2B Sectors — Detailed Engineering Use Case:
| Sector / Application | Engineering Use Case Details |
| Small commercial buildings | Installation in small offices, retail shops, and private clinics needing coverage of up to 24 zones without the complexity or cost of large addressable systems |
| Small-scale industries and production workshops | Covering limited-area production workshops and raw material stores, benefiting from support for up to 25 detection devices and call points per zone to cover multiple hazard points within a single operational space |
| Upgrade and legacy system replacement projects | Replacing old or damaged conventional control panels in existing buildings without needing a full rewiring, benefiting from direct compatibility with pre-existing conventional detectors and call points |
| Fire safety and protection systems contractors | Supplying integrated fire alarm installation projects with a reliable, certified central component that integrates directly with the full range of BLITZ conventional devices (detectors, call points, sounders, bells) |
| Small to medium warehouses | Providing full multi-zone coverage for medium-sized storage spaces, with the ability to separate each storage zone from another for precise fire location identification upon activation |
| Small educational and healthcare facilities | Installation in schools, clinics, and small care centers requiring a reliable alarm system within a limited budget, without the complexity of larger addressable systems |
Supply Information
| Field | Value |
| Lead Time | 2-3 working days |
| Coverage | Riyadh · Dammam · Jeddah · Jubail · Yanbu · All KSA |
| Project Supply | Available — contact B2B team for complete fire alarm system project supply (panel + detectors + call points + sounders) |
Frequently Asked Questions
Q1: Is this panel compatible with other BLITZ smoke detectors, heat detectors, and call points?
- Yes, the panel is a conventional system directly compatible with all other BLITZ conventional devices (smoke detector, heat detector, manual call point, and sound/light alarm devices), supporting up to 25 combined devices per zone.
Q2: What is the difference between a conventional and an addressable panel?
- A conventional panel identifies a fire at the full "zone" level (up to 24 zones on this model), while an addressable panel identifies the exact device triggering the alarm. Conventional panels suit small to medium buildings where precise location identification is less critical than in larger projects.
Q3: What happens during a mains power outage?
- The panel includes a built-in backup battery with over-discharge protection, ensuring continued alarm system operation during a mains supply (AC 220-230V) outage.
Q4: How many devices can be connected per zone?
- Each zone supports up to 25 combined devices, including smoke detectors, heat detectors, and manual call points (MCPs).
Q5: Is delivery available to Riyadh, Dammam, and all KSA regions?
- Yes, supply is available across all KSA regions with bulk quantities available for B2B projects.
Internal Links
- Complete the alarm system: browse the BLITZ conventional smoke detector and BLITZ conventional heat detector, both directly compatible with this panel.
- Add BLITZ manual call points and sound/light alarm devices (indoor and outdoor) and the mechanical fire alarm bell — all directly compatible with this panel's zones.
- Browse all BLITZ products available at Al-Najma Al-Wataniyah.
- Need to fit out a complete project with a compatible control panel and alarm devices? Contact our B2B team for quotes and compliance documentation, including Civil Defense approval verification.
_________________________________________________________________________________________
Copyright © 2026 - (Al-Najma Al-Wataniyah Est.) · All Rights Reserved · KSA
We are committed to providing the highest quality standards for our customers in the Kingdom of Saudi Arabia; approved certificates or technical data sheets are available for every product to ensure your project requirements are met.
Questions you might have