Vital signs monitor device, 15-inch touchscreen, with printer, model K15

5800

بدون co2
مع co2

Product description

General Features and Design: Screen and Interface: Color touchscreen 15 inch size with flexible and comfortable user interface based on Windows system window display style. Waveform display: Ability to view up to 9 waveforms simultaneously on the screen. Patient sections: Dedicated to monitoring vital signs for all age groups: adults, children, and newborns. Alarm system: Smart visual and audio alarms divided into 3 levels of severity for physiological and technical warnings. Data storage: Large internal storage capacity for saving patient vital records. Data transfer and updates: Equipped with a USB port for exporting vital data and easily updating software. Software and cloud support: Compatible with computer operating systems (Windows XP, 7, 8, 10, 11) for data tracking. Supported system languages: English, German, French, Portuguese, Spanish, Italian, Polish, Turkish, and Russian. Safety & Interference: Approved safety standard: Designed according to international medical standards IEC 60601-1. Oxygen sensors: Supports operation with original high-precision Nellcor sensors. Shock protection: Equipped with an integrated insulation and protection system against defibrillator discharges to protect the patient and device. Interference resistance: Designed to resist wave interference and noise caused by electrosurgical units. Pacemaker detection: Recognizes signals from artificial pacemakers and inhibits related interference signals. Measurement Specifications: 1. ECG & Heart Rate (HR) ECG cable: Supports 5-lead system. Dynamic input range: ±(0.5 ~ 5 mVp). Differential input resistance: ≥ 10 MΩ. Frequency ranges: Diagnostic: 0.05 to 150 Hz. Normal monitoring: 0.5 to 40 Hz. Operation rooms: 1 to 20 Hz. Common mode rejection ratio (CMRR): ≥ 90 dB in diagnosis, ≥ 105 dB in monitoring and operations. Sensitivity levels: × 1/4, × 1/2, × 1, × 2, × 4, with automatic detection feature. Wave sweep speed: 6.25, 12.5, 25, 50 mm/sec. Heart rate measurement range: 15 to 350 bpm, with error rate ± 1% or ± 2 bpm (whichever is greater). 2. Respiration (RESP) & Temperature (TEMP) Measurement range: Respiration from 0 to 120 breaths per minute (rpm) with error rate ± 5% or ± 2 breaths/min. Temperature range: 21.0 to 50.0 degrees Celsius, with accuracy up to ± 0.2 degrees Celsius in critical clinical range (25-45 Celsius). 3. Non-invasive Blood Pressure (NIBP) Operation mechanism: Oscillometric with standard measurement time for adults less than 30 seconds. Operating modes: Manual, Auto, STAT cycle, Multi-cycle mode. Automatic measurement intervals: Adjustable from 1 minute to 480 minutes. Measurement ranges (by age group): Systolic (SYS): Adults (40-275), Children (40-200), Newborns (40-135) mm Hg. Diastolic (DIA): Adults (10-210), Children (10-150), Newborns (10-95) mm Hg. Mean arterial pressure (MAP): Adults (20-230), Children (20-165), Newborns (20-110) mm Hg. Accuracy: Average error difference ± 5 mm Hg with standard deviation estimated at 8 mm Hg. 4. Blood Oxygen (SpO2) Technique: Dual-wavelength optical examination. Range and accuracy: Total range 0% - 100%, error ± 2% between 70% and 100%. Peripheral pulse rate (PR): 30 to 250 bpm with accuracy ± 2 beats or ± 2%. Low perfusion rate: Excellent accuracy even at very low blood flow up to 0.3%. 5. Advanced Invasive Blood Pressure (2-IBP) Technique: Voltage meter converter power supply. Measurement range: Wide range from 50 to 300 mm Hg with accuracy ± 2% or ± 4 mm Hg. Multiple measurement channels: Supports arterial, venous, and internal sites: ART, RAP, PA, LAP, CVP, ICP, AUXP1, AUXP2. Calibration: Instant automatic zero calibration feature to ensure reliable results. 6. End-tidal CO2 (EtCO2) Measurement Technique: Infrared optical absorption. Sampling modes: Supports sidestream or mainstream. Measurement range: 0 to 150 mm Hg. Varying measurement accuracy: 0-40 mm Hg: accuracy exceeds ± 2 mm Hg. 41-70 mm Hg: error up to ± 5% of reading. 71-100 mm Hg: error up to ± 8% of reading. 101-150 mm Hg: error up to ± 10% of reading. Sample flow rate: 50 ml/min ± 10 ml/min (sidestream mode). Power & Networking: Power source: Flexible AC power (AC 100-240 V) at 50/60 Hz with 60 VA power consumption. Internal rechargeable battery: Lithium-ion battery 11.1V / 4400 mAh ensures continuous operation during power outages or patient transfer. Network connection: Built-in Ethernet port for connecting the device to the hospital’s central monitoring station.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌