DSPPA DMA500U 500W 100V Mixer Amplifier for Large Spaces

2477.15

Product description


The DSPPA DMA500U is a 500W digital mixer amplifier that still delivers 250W from a DC 24V source, with 100V or 4-16 ohm output. It serves warehouses, compounds and showrooms that need dozens of speakers on one line, with paging, music and an emergency input.

====

The DSPPA DMA500U delivers 500W on mains, which makes it the pick in this series when the space is large and the speaker line is long. A warehouse with long aisles, a residential compound with courtyards and parking, or a showroom with several halls all need enough power for many speakers on a 100V line. On a 24V DC supply it still gives 250W, so paging stays available during a power cut.

Why choose the DSPPA DMA500U for large spaces

On a 100V line you add up the tap wattage of every speaker, and the total must stay below the amplifier's rating. At 500W, the DMA500U has room for a large number of small ceiling speakers or a mix of horns and wall speakers. From DSPPA's official datasheet:

  • Power: 500W on AC, 250W on DC 24V.
  • Output: 100V constant voltage or 4-16 ohm, set by a rear switch.
  • Mains: AC 110-115V or 220-230V, switch-selectable.
  • DC input labelled 33A.
  • AUX response of 80Hz-15kHz and THD under 1%.

Paging and emergency in big facilities

In a warehouse or factory, the system's main job is getting the message out on time. MIC1 overrides music, EMC messages, siren and chime override the mic, and MUTE sits above everything. The EMC input (350mV) takes a pre-recorded message from another panel, and the SIREN input fires on a contact closure with its own alarm output. Chimes are blocked during an alarm so the siren stays clear.

Audio inputs and background music

MIC1 is on the front, and MIC2 and MIC3 are balanced on the rear with 48V phantom. MIC3 switches to AUX2, and there is also AUX1 plus an AUX OUT for linking a second amplifier as the system grows. For corridor and hall music use Bluetooth, a USB stick or FM, all controllable from the remote. Chime 1 and Chime 2 sit on the front panel with levels 0-15.

Installation and size

The unit is 380 mm wide, 430 mm deep and 88 mm tall, weighing 6.3 kg net. It runs from -10 to 50°C at 20-80% humidity, so keep the equipment room ventilated in summer. Power-off memory keeps your settings after an outage.

Where the DMA500U fits in Saudi Arabia

  • Warehouses and distribution centers in Riyadh and Dammam: horn-speaker paging across aisles and yards.
  • Residential compounds: speakers in courtyards, the clubhouse and parking.
  • Showrooms and small malls: background music and paging across several halls.
  • Factories: paging with a siren triggered from an external panel.

DMA500U, DMA350U or DMA2500?

The DMA350U shares the same size, inputs and output switch, but gives 350W on mains, 175W on DC and has a 26A DC input. The DMA2500 has two 500W channels, 6 mic inputs and built-in reverb and is designed for mosques. Choose the DMA500U when your speakers total 350W to 500W and you need a single paging and music channel.

Frequently Asked Questions

What power does the DMA500U give on 24V?

250W according to the official table, against 500W on mains. The rear DC input is labelled 33A.

Can I connect 8 ohm speakers?

Yes. Set the rear output switch to 4-16 ohm instead of 100V and connect speakers within that range.

How does the DMA500U differ from the DMA2500?

The DMA500U is a single 500W channel with Bluetooth, USB, FM, chimes and a siren trigger. The DMA2500 has two 500W channels, 6 mic inputs and built-in reverb, aimed at mosques.

Specifications

  • Model: DMA500U
  • Series: DMA60U Series (DMA60U to DMA650U)
  • Rated output (AC): 500W
  • Rated output (DC 24V): 250W
  • Speaker output: 4-16Ω or 100V (constant voltage), switch-selectable
  • Microphone inputs: MIC1 front, MIC2 and MIC3 balanced on rear
  • AUX inputs: 2 (AUX2 shared with MIC3 via selector switch)
  • Emergency input: 1× EMC input
  • Line output: 1× AUX OUT
  • Phantom power: +48V for MIC2/MIC3, rear switch
  • MIC1 / MIC2 sensitivity: 10mV ±1mV
  • AUX1 / AUX2 / EMC sensitivity: 350mV ±50mV
  • MIC frequency response: 120Hz-12kHz (±3dB)
  • AUX frequency response: 80Hz-15kHz (±3dB)
  • THD: <1%
  • SNR (A-weighted): AUX ≥75dB, MIC ≥71dB
  • Tone controls: Bass and treble ±10dB (±2)
  • Built-in sources: USB, Bluetooth, FM radio (with FM antenna socket)
  • Chimes and alarms: Chime 1 and Chime 2 (level 0-15), SIREN short-circuit trigger with alarm output, MUTE short-circuit trigger
  • Priority: MUTE > EMC = Alarm = Chime > MIC1 > others (no chime during alarm)
  • Control and display: Segment display, IR remote control, power-off memory
  • AC power supply: AC 110-115V or AC 220-230V, 50/60Hz (switchable)
  • DC input (rear-panel label): 24V / 33A
  • Rear-panel switches: Output mode switch (4-16Ω / 100V), AC voltage selector, phantom switch, AUX2/MIC3 selector, MIC and alarm gain
  • Operating temperature: -10 to 50°C
  • Relative humidity: 20% to 80%
  • Dimensions (D × W × H): 430 × 380 × 88 mm
  • Net weight: 6.3 kg

Features

  • 500W on mains: drive a large number of ceiling and horn speakers on a single 100V line.
  • 250W on DC 24V through a 33A input: half the power stays available from a backup system during an outage.
  • 100V or 4-16 ohm output switch: one unit for long speaker runs or for professional low-impedance cabinets.
  • EMC input at 350mV and SIREN trigger with alarm output: emergency messages and sirens override mic and music.
  • Bluetooth, USB and FM with remote control: background music for corridors and halls with no separate player.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌