Fanvil CL-01 Nurse Call Corridor Light, Colour LED and RS485

95.07

Product description


The Fanvil CL-01 is a corridor light that mounts at the patient room entrance and changes colour by call level, so staff can spot the calling room from the corridor. It takes 12V DC and RS485 control from the Y501-Y intercom and measures 78 × 86 × 46 mm.

====

The Fanvil CL-01 is a small signal light that sits above a patient room door and glows in a colour that tells staff the call level. A nurse walking down the ward can see which room is calling, and whether it is routine or urgent, without walking back to the station. The light works with the Fanvil Y501W-Y and other Y501 and Y501-Y series intercoms, taking both power and commands from them over RS485.

Fanvil CL-01 specifications

Figures from Fanvil's official product page:

  • Dimensions: 78 × 86 × 46 mm.
  • Housing: white ABS.
  • Power: 12V DC.
  • Interface: RS485 on a 4-pin PH 2.0 mm connector.
  • Mounting: 86-type back box or wall surface.

A colour code your staff read at a glance

On long wards, minutes disappear every time a nurse returns to the station to check where a call came from. With a CL-01 over each door, a look down the corridor is enough. Fanvil uses different colours to separate call levels. When no emergency is active, statuses can rotate with a slow flash.

Wiring: one cable from the room unit

There is no power adapter or network port to plan for. A 4-wire cable runs from the Y501-Y intercom inside the room and carries both 12V power and control. You need one light per room, and the 78 × 86 mm footprint matches the 86-type electrical boxes common in Saudi buildings, so it fits neatly over the door frame.

Light behaviour set from the nurse call system

The latest Fanvil FNCS release note adds an option to switch the light off once a call is answered, plus 2 display modes: priority first, or priority followed by rotation of routine statuses. After attending the patient, the nurse presses 0 on the room unit to reset the light and stop repeat reminders.

Where the CL-01 goes

  • Hospital inpatient wards, above every room fitted with a Y501W-Y.
  • Nursing homes where staff cover several corridors.
  • Recovery and observation rooms in clinics and medical centres.
  • Ward bathrooms, so a KT30 pull-cord call shows above the door.

How many lights does your project need?

The rule is simple: one CL-01 per room fitted with a Y501-Y, since the light draws power and control from that room unit. A 24-room ward needs 24 lights and 24 Y501W-Y units, plus one A320i console that manages up to 100 devices in standalone mode. In a twin room there is still one light over the door, and the bed number appears on the console. Measure the cable run from the room unit to the top of the door frame before first fix.

CL-01 or CMD-01 corridor display?

The CL-01 is a per-room light wired to the Y501-Y in that room, and it only gives a colour signal. The CMD-01 is a double-sided LED dot-matrix sign hung in the corridor; it shows call text, holds up to 30 messages sorted by priority in red, green and yellow, and is managed from the A320i nurse console. Most projects use both: a CL-01 over each door and a CMD-01 mid-corridor or at the nurse station.

Frequently Asked Questions

Does the CL-01 need a power adapter?

No. It takes 12V DC and control from the Y501-Y intercom in the room over a 4-wire RS485 cable.

Will the CL-01 work without a Y501W-Y?

Fanvil lists it as compatible with the Y501 and Y501-Y series only, so one of those units must be in the room.

Specifications

  • Model: CL-01
  • Type: Nurse call corridor light
  • Applicable models: Y501 / Y501-Y Series
  • Dimensions: 78mm × 86mm × 46mm
  • Material: ABS
  • Device colour: White
  • Power: 12V DC (supplied by the Y501-Y)
  • Communication protocol: RS485
  • Connection: 4PIN PH=2.0MM
  • Installation: 86-type box or surface mount, above the room door (one per room)
  • Display modes: Priority first / priority then routine rotation

Features

  • Colour LED: one colour per call level, so the nurse knows the priority before entering.
  • 12V DC and RS485 control from the Y501-Y: no separate power supply or network point needed.
  • 78 × 86 × 46 mm, fits an 86-type box: a tidy install above the door on standard electrical boxes.
  • 2 display modes: priority first, or priority then rotation of routine statuses.
  • Reset with key 0 or switch off on answer: the nurse clears the alert from inside the room.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌