DSPPA MAG6801 1-Channel IP Audio Terminal with Dual Network Ports

1355.05

Product description


The DSPPA MAG6801 is a one-channel IP audio terminal that receives streams from the system server and outputs line-level audio to an existing amplifier. It suits buildings that already have 100V amps and speakers and want them on an IP PA system, with an emergency input and two server-controlled alarm outputs.

====

The DSPPA MAG6801 is a one-channel network audio terminal that connects an existing amplifier to the DSPPA MAG6000 IP PA system. It receives streams from the system server over two 10/100M network ports and outputs a 1V line-level signal straight into the amp. If a building already has working 100V amplifiers and speakers, each amp can become a network-managed zone without new speakers or cabling.

DSPPA MAG6801 specifications

  • One channel with a constant 1V output.
  • Two network ports, LAN1 and LAN2, 10M/100M with redundancy.
  • MP3, WAV and PCM decoding up to 48kHz and 16-bit.
  • EMC emergency input, 20Hz-20kHz, THD no more than 0.1%.
  • COM-24V output at 1A and a COM-SC short-circuit output.
  • 5W standby and 7.5W rated consumption.

An emergency path that bypasses the network

An EMC LINE IN on the rear accepts audio from the fire control center, and an EMC LINK OUT passes it to the emergency amplifier at virtually the same level (±10%). The input handles 250mV to 4V and has a level trim. An override input gives emergency audio priority over normal programming.

If this path forms part of a voice evacuation system, confirm your project's requirements with the safety engineer before relying on it.

Server-controlled outputs

The COM-24V output supplies 24V at up to 1A in total, and the COM-SC output closes a short circuit below 1Ω. The server controls each one independently.

Hands-off operation

Once configured in the management software, the MAG6801 needs no local operation. A built-in watchdog restarts it if it hangs, and the second network port keeps the link alive or chains another device. The front panel has a 1W monitor speaker with an on/off switch and volume knob, so a technician can confirm the stream right at the unit.

Typical projects in Saudi Arabia

  • An existing school with 100V amplifiers moving to IP paging run from the admin office.
  • A multi-building hospital where each building's amplifier takes audio from one server.
  • A commercial complex linking car park and corridor amplifiers to a single control room.
  • A hotel upgrading in stages: keep the amplifiers and add networking first.

Compatibility and installation

The MAG6801 works with a system server such as the MAG6182II and with the MAG6588, MAG6510 and MAG6585 paging stations. It is 483 mm wide and 44 mm tall. Power is AC220V/50Hz.

MAG6801, MAG6804 or MAG6701?

The MAG6801 serves one amplifier on one channel. DSPPA lists the MAG6804 as a four-channel terminal, so one box feeds four amps. The MAG6701 is a different type altogether: a wall-mount endpoint with its own 60W 100V amplifier and no external amp needed. Choose the MAG6801 to put a single existing amplifier on the network.

Frequently Asked Questions

Does the DSPPA MAG6801 have a built-in amplifier?

No. It outputs 1V line level to an external amplifier. For a built-in 60W amp, see the MAG6701.

How many channels does the MAG6801 have?

One. DSPPA offers the MAG6804 for four channels in a single unit.

Can the MAG6801 accept a signal from the fire alarm system?

Yes. Its EMC LINE IN takes emergency audio from the fire control center, and EMC LINK OUT passes it to the emergency amplifier.

Specifications

  • Model: MAG6801
  • Type: 1-channel network system audio terminal
  • System: DSPPA MAG6000 IP network PA system
  • Network: Dual 10M/100M ports (LAN1, LAN2) with redundancy
  • Decoding: MP3, WAV, PCM up to 48kHz, 16-bit
  • EMC LINE IN output: CH1 constant output 1V
  • Input sensitivity: Max 4V, min 250mV
  • EMC input frequency range (±3dB): 20Hz-20kHz
  • EMC input S/N (30kHz low pass): ≥70dB
  • THD (1kHz, 1/3 output voltage): ≤0.1%
  • EMC LINK output: Equal to EMC LINE input (±10%)
  • Input dynamic range: ≥26dB
  • Network decoding (host MP3): CH1 constant output 1V
  • Network decoding distortion (1kHz -10dB/MP3): ≤0.2%
  • Network frequency range (±3dB): 50Hz-20kHz
  • Network S/N (30kHz low pass): ≥70dB
  • COM-24V output: 24V, 1A total current
  • COM-SC output: Short circuit (under 1Ω)
  • Built-in monitor: 1W with MONITOR switch and volume knob
  • Rear panel: Network LED, LAN1/LAN2, override input, input level adj., EMC LINK OUT, audio output to amplifier, COM-24V/COM-SC alarm output, AC220V socket
  • Other: Built-in watchdog, customizable network protocol interface, local volume, configured via management software
  • Power supply: AC220V/50Hz
  • Standby power: 5W
  • Rated power consumption: 7.5W
  • Unit dimensions (L×W×H): 483×273×44 mm
  • Net weight: 3.3 kg

Features

  • One channel with 1V line output: connect any existing amplifier and it becomes a zone on the IP system.
  • Dual 10/100M network ports with redundancy: stays online if one path fails, and links to other network gear.
  • EMC emergency input with EMC LINK output: passes emergency audio from the fire control center to the emergency amplifier.
  • COM-24V output at 1A plus a COM-SC short-circuit output: alarm outputs controlled by the server.
  • 1W front monitor speaker with switch and volume: technicians confirm the stream right at the unit.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌