DSPPA MAG6182II IP Network PA Center with 17.3-inch Touch Screen

22584.02

Product description


The DSPPA MAG6182II is the central server of the DSPPA MAG6000 IP PA system, pairing an Intel Core i7 board with a 17.3-inch touch screen to run zones, schedules and emergency calls over the LAN. It fits schools, universities, malls and large campuses that need one control point for dozens of IP terminals.

====

The DSPPA MAG6182II is the control server at the heart of DSPPA's IP network PA system. It sits in the control room and streams audio over the LAN to IP terminals and network amplifiers in every zone. Inside one chassis you get a program player, scheduler, zone manager, equalizer and audio matrix, all driven from a 17.3-inch touch screen. DSPPA positions it for airports, schools, universities, stadiums, industrial parks and transport networks.

DSPPA MAG6182II hardware and capacity

The unit is an industrial PC on a server-grade board, built for a standard 19-inch rack:

  • Intel Core i7-9750H processor with 8GB DDR4 memory.
  • Two SSDs: 250GB M.2 plus 512GB 2.5-inch.
  • Windows 7 or later, 32 or 64-bit.
  • MP3 playback at 120 to 320 kbps.
  • Under 110 terminals in unicast mode, unlimited in multicast.

At the back, an HDMI output (or VGA) drives an external monitor in the control room, and a key switch controls power so nobody shuts the system down by accident. Audio figures: line SNR above 70dB and distortion under 0.5% at 1kHz.

Emergency controls on the front panel

A FULL ALARMING button opens every zone at once for an alarm broadcast. Next to it is the handheld emergency mic jack, which overrides all other audio. The datasheet refers to DSPPA's CB-100 emergency paging mic for this input. The front panel also carries a USB port for flash drives or external disks and a slot-loading CD player.

Scheduling, monitoring and automation

Build a timetable per zone and set the volume of each scheduled item separately. If a terminal drops off the network and comes back, playback resumes on its own. Other software features DSPPA lists:

  • Text-to-speech in Chinese and English.
  • Live view of playback status and volume per zone, with new zones added automatically.
  • Broadcast recording and an operation log.
  • Linkage with Hikvision and Dahua cameras for AI-triggered announcements, plus H.264 video terminal management, intercom access and electronic maps.

Redundancy and modular expansion

The system supports a second unit as a hot backup, with two databases syncing in real time, and dual LAN ports for network redundancy. The chassis is modular. DSPPA states it needs six standard modules to run: a switch module, a 4-channel audio collection module, a monitoring module, a hard disk module and main and standby power modules.

Typical projects in Saudi Arabia

  • Schools: morning assembly broadcasts and programmed class bells per building or floor.
  • Malls: zoned background music, visitor announcements and a single-button all-zone alarm.
  • Universities and hospitals: separate buildings on one network, controlled from a central room.
  • Hotels and conference venues: different programs for the lobby, restaurants and corridors.

MAG6182II, MAG6182L or MAG6183C?

The MAG6182L shares the same screen, terminal capacity and chassis size but runs Ubuntu 22.04 on a Core i7-7500U, while the MAG6182II runs Windows on an i7-9750H. The MAG6183C is a 2U rack host with no built-in screen (HDMI and VGA outputs), a Core i5-10400 and a 500GB SSD. Around the MAG6182II, the MAG6310 is a 2x15W amplified terminal and the MAG6402 is a wall control panel.

Frequently Asked Questions

How many terminals can the MAG6182II control?

Under 110 in unicast mode and an unlimited number in multicast mode, according to DSPPA's datasheet.

Does the MAG6182II need extra modules?

DSPPA says it needs six standard modules to run: switch, 4-channel audio collection, monitoring, hard disk, and main and standby power. Confirm what is fitted before ordering.

Can it trigger an alarm in all zones at once?

Yes. The FULL ALARMING button opens every zone, and the emergency mic input has the highest priority.

Specifications

  • Model: MAG6182II
  • Type: Network public address center
  • System: DSPPA MAG6000 IP network PA system
  • Computer system: Windows 7 or later, 32/64-bit
  • CPU: Intel Core i7-9750H
  • Memory: 8GB DDR4
  • Storage: 250GB M.2 SSD + 512GB 2.5-inch SSD
  • Playback format: MP3
  • Stream rate: 120 to 320 kbps
  • Supported terminals: Under 110 unicast; unlimited multicast
  • Screen: 17.3-inch LCD
  • Control: Touch screen, key-switch power control
  • Timing power load capacity: 2A per channel
  • System audio SNR: LINE >70dB; MIC >60dB
  • System audio distortion: <0.5% at 1kHz
  • Standard input level: LINE: 300mV ±20mV; MIC: 10mV ±2mV
  • Standard output level: 0dBV
  • Power output method: Constant resistance output
  • Undistorted output power: 10W
  • Front panel: USB port, slot-in CD player, EMC MIC emergency mic jack, FULL ALARMING button
  • Rear panel: HDMI (or VGA), LAN1/LAN2, MIC IN, LINE IN, LINE OUT, CH1 to CH4 inputs, power inlet
  • Standard modules: Requires 6 standard modules: switch, 4-channel audio collection, monitoring, hard disk, main and standby power
  • Mounting: 19-inch rack
  • Power: AC 220V / 50Hz, 150W
  • Unit dimensions (L×W×H): 483×308×445 mm
  • Net weight: 19.5 kg
  • Software: Network PA system software package

Features

  • 17.3-inch touch screen: pick zones, start programs and watch each zone's status right on the unit.
  • Up to 110 unicast terminals, unlimited multicast: one center covers a large building or a whole campus.
  • One-key all-zone alarm plus a top-priority emergency mic input: evacuation messages reach every zone at once.
  • Two SSDs, 250GB M.2 and 512GB 2.5-inch: room for program libraries, recordings and scheduled messages.
  • Master and backup hot standby with real-time database sync and dual network ports: the system is built to keep running if the main unit or one network link fails.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌