DSPPA MAG1116 10-Zone PA Center with 5-inch Touch Screen

4215.68

Product description


The DSPPA MAG1116 is a 10-zone public address center that handles background music, weekly scheduling, paging and fire alarm triggers from one unit. It fits schools, warehouses and supermarkets building a mid-size system around external power amplifiers.

====

The DSPPA MAG1116 is a 10-zone public address center that rolls background music, a weekly timer, remote paging and fire alarm triggers into one unit. DSPPA pitches it as a cost-effective choice for small and mid-size sites such as schools, supermarkets and factories. You run it from a 5-inch touch screen on the front panel. It runs on 220V mains, and a MAG1116D variant adds a 24V DC backup input.

DSPPA MAG1116 key specifications

There is no amplifier inside. The MAG1116 takes the output of your power amplifiers and routes it to speaker lines by zone and schedule. It supports up to 5 background music amplifiers and 1 emergency/paging amplifier, each up to 2000W.

  • 10 built-in zones; each amplifier channel feeds two zones (channel 1 drives zones 1 and 2, and so on).
  • About 200W average per zone, 2000W total.
  • 1G of built-in memory plus a USB port for MP3 playback, song transfer and timer backups.
  • A 4Ω / 10W monitor output to listen to any zone from the equipment room.

A weekly timer you set once

The unit stores 5 programs with up to 200 time points each. Every point picks the zones, up to 20 MP3 tracks, the state of the rear power outlets and an optional end time. Programs repeat on a cycle or run on a set date, so a school can keep one schedule for teaching days and another for exam weeks. Four timed AC outlets (220V, 2000W total) switch the amplifiers on before the first bell and off after the last class.

Emergency paging and fire alarm input

The front emergency microphone overrides every other source, and a single alarm button sends the tone to all zones. Ten short-circuit inputs on the back accept a fire panel signal, either high (+5V to +24V) or low (0V). You can record an evacuation message of up to 10 minutes through the front MIC or LINE input and play it with a dedicated button. The same inputs record up to 4 hours of background music.

Paging from other rooms

Two 9-pin ports take remote paging microphones, there is a wireless mic input, and an RJ45 port links to a PC for uploading songs and editing the timer remotely. For routine announcements you select one or more zones first, so only those areas hear you. Note that the menu language is Chinese or English.

Where it fits in Saudi Arabia

  • Schools: class bells, morning assembly and school radio across classrooms, yard and prayer hall.
  • Warehouses and factories: staff paging per hall, with alarms tied to the fire panel.
  • Supermarkets and large shops: background music and promotion announcements in chosen sections.
  • Small clinics: reception paging and quiet music in waiting areas.

MAG1116 or MAG2120II?

The MAG1116 switches external amplifier output across 10 zones, with a 5-inch screen, two remote paging ports, 1G memory and an 88 mm tall chassis. The MAG2120II is an 8-input, 20-zone audio matrix with a 7-inch screen, four remote paging ports, 6G storage, AM/FM radio, Bluetooth and telephone paging. Pick the MAG1116 for up to 10 areas; step up to the MAG2120II when you need different sources in more zones.

Frequently Asked Questions

Does the MAG1116 have a built-in amplifier?

No. It works with external amplifiers: up to 5 for background music and 1 for emergency paging, 2000W max each.

Can it connect to a fire alarm panel?

Yes. It has 10 short-circuit trigger inputs, an internal alarm tone and a front alarm button that covers all zones.

What languages does the screen support?

The official datasheet lists a Chinese or English interface.

Specifications

  • Model: MAG1116 (MAG1116D variant adds 24V DC backup input)
  • Type: 10-zone intelligent public address center
  • Zones: 10 built-in zones, each amplifier channel feeds two zones
  • Display: 5.0-inch resistive touch screen with level indication
  • Interface language: Chinese or English
  • Built-in memory: 1G
  • USB: MP3 playback (MP3 only), song and timing-point import/export, firmware upgrade
  • Emergency recording: Up to 10 minutes in MP2 via front MIC or LINE input
  • Background music recording: Up to 4 hours via front MIC or LINE input
  • Microphone inputs: Front emergency mic (highest priority), 2 remote paging inputs (9-pin D), 1 wireless mic input
  • Line outputs: Line A for MP3 source, Line B for emergency and paging
  • Supported amplifiers: Up to 5 background + 1 emergency amplifier, 2000W max each
  • Power per zone: About 200W average, 2000W total max
  • Alarm inputs: 10 short-circuit trigger inputs, high (+5V to +24V) or low (0V), internal alarm tone
  • Short-circuit output: 1 (low level)
  • Timer: 5 programs, up to 200 points each, cyclic or by date, up to 20 MP3 files per point
  • Timed power outlets: 4 channels, 220V / 2000W total max, plus 1 short-circuit control input
  • Monitor output: 4Ω / 10W (1kHz, 1% distortion)
  • Network port: RJ45 to PC: song download and remote timer editing
  • Input sensitivity: Local mic 2 to 3.5 mV; wireless mic 200 to 350 mV; remote paging 1000 ±100 mV; MP3 and line recording 200 to 350 mV
  • Maximum noise: ≤0.5 mV (A/B, wireless mic); ≤1 mV (B, local mic); ≤1.5 mV (monitor)
  • Distortion: ≤0.3% (line input); ≤0.5% (local mic)
  • Frequency response (±3dB): Mic and remote paging 50Hz-20kHz; wireless 100Hz-20kHz; MP3 200Hz-20kHz; line recording to A 350Hz-20kHz, to B 100Hz-10kHz
  • Monitor level: 6-7.5V on 220V; 5-6V on 24V
  • Power and protection: AC 220V / 1A; DC +24V / 2A (MAG1116D only)
  • Dielectric strength: 4200 VDC power to I/O; 2200 VDC power to chassis
  • Dimensions: 483 × 350 × 88 mm
  • Net weight: 8 kg

Features

  • 10 zones and 10 fire alarm inputs: a signal from the fire panel starts the alarm with no operator action.
  • 5 timer programs with 200 points each: bells, assembly announcements and music run on their own every week.
  • Up to 5 background amplifiers plus 1 emergency amplifier, 2000W max each: size the system to the building.
  • Front-panel emergency recording up to 10 minutes: record your evacuation message and play it with one button.
  • 2 remote paging mic inputs and 1 wireless mic input: page from the principal's office or reception desk.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌