DSPPA MP9815E PA System Emergency Unit with 60 s Recorded Message

1626.05

Product description


The DSPPA MP9815E is an emergency unit from DSPPA's analog MP98 PA series. When the fire panel closes its alarm contact, it outputs a siren or a 60-second recorded evacuation message into the PA chain, which suits 100 V systems in schools, factories, warehouses and malls.

====

DSPPA's MP9815E is a modest rack unit that decides what people hear the moment an alarm goes off. Part of DSPPA's analog MP98 PA series, it plays a siren or a 60-second recorded evacuation message as soon as the fire panel closes its alarm contact. If your building runs a conventional 100 V PA system, this is the piece that turns background music speakers into a voice that tells people where to go.

DSPPA MP9815E specifications

  • Mic input 2 mV and line input 1 V, both at 10 kΩ.
  • Alarm input triggered by a 0 V short circuit.
  • 1 V output carrying the siren or recorded message.
  • 60-second internal recorder, 100 Hz to 10 kHz (±3 dB) response.
  • AC 220 V / 50 Hz power with fuse protection.

Record the message in your own voice

A generic siren tells visitors something is wrong but not what to do. With the MP9815E you record a clear instruction instead, for example "Please leave the building by the nearest emergency exit". Record straight from a microphone or from a line source; the clip is stored on a chip inside the unit. Front-panel knobs set the record level and the output volume, so the message comes out clean and at the right loudness. Arabic, English or both fit, as long as the whole message stays within 60 seconds.

What happens when the alarm trips

The alarm input treats 0 V, a closed contact, as active. A dry relay output from the fire panel is all it needs, with no external voltage. Once triggered, the unit sends a 1 V siren or message signal through the mixer and amplifiers to the speakers. DSPPA positions it for alerting and guiding people across large sites such as stadiums, campuses and transport hubs.

Typical Saudi applications

  • Schools with a conventional PA, gaining a ready-made evacuation message for drills.
  • Factories and warehouses that need a loud siren over machine noise.
  • Older malls and commercial centres adding evacuation messaging to an existing 100 V system rather than replacing it.
  • Wedding halls and conference venues that must give guests clear instructions in an emergency.

Part of the MP98 family

The unit measures 484 × 365 × 88 mm and weighs 7.1 kg. DSPPA's MP98 range also includes the MP9821M main/standby amplifier switcher, the MP9810RII remote paging microphone and the MP9819A alarm matrix, so you can build a complete system from one range.

MP9815E or MP9821M?

Both belong to the MP98 series, share the 484 × 365 × 88 mm chassis and run on 220 V, but they solve different problems. The MP9815E is an emergency audio source: it generates the siren or recorded message when the alarm trips. The MP9821M protects the amplifier stage: it watches 4 amplifiers and moves their lines to a standby amplifier on failure. For a networked DSP9100 system, the right fire-alarm link is the DSP9102 instead.

Frequently Asked Questions

How long a message can the DSPPA MP9815E store?

60 seconds on its internal recording chip, recorded from a mic or a line source.

How does it connect to the fire panel?

Its alarm input triggers on a 0 V short circuit, so a dry relay contact from the panel is enough.

Does it need an amplifier?

Yes. It outputs a 1 V signal, which goes through the PA mixer or amplifier before reaching the speakers.

Specifications

  • Model: MP9815E
  • Series: MP98 analog PA system
  • Mic input: 2 mV, 10 kΩ
  • Line input: 1 V, 10 kΩ
  • Alarm input: 0 V (short circuit) is valid
  • Output: Siren or recorded message: 1 V
  • Recording: Built-in IC, 60 s
  • Frequency response: 100 Hz-10 kHz (±3 dB)
  • Controls: Record level, output volume
  • Protection: AC fuse
  • Power requirement: AC 220 V / 50 Hz
  • Unit size (L × W × H): 484 × 365 × 88 mm
  • Net weight: 7.1 kg

Features

  • 60-second built-in digital recorder: record the evacuation message from a mic or line source and keep it in the unit.
  • 0 V short-circuit alarm trigger: a dry relay contact from the fire panel is enough to start the siren or message.
  • 1 V siren or message output: feeds straight into the mixer or amplifier in the PA rack.
  • Separate record level and output volume controls: set message clarity and loudness from the front panel.
  • 100 Hz to 10 kHz (±3 dB) response: tuned for intelligible speech in corridors and halls.

Questions you might have

‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌
‌
‌‌
‌