KYORITSU KEW 3125A 5 kV Insulation Tester with PI and DAR

3680

5719.87-36%

Product description

KYORITSU KEW 3125A 5 kV Insulation Tester with PI and DAR

The KYORITSU KEW 3125A applies selectable test voltages from 250 to 5000 V to assess cable, motor and equipment insulation under a defined maintenance procedure. Resistance and test-voltage indications, together with automatic PI and DAR calculations, help the technician compare insulation behaviour over time.

Key Features

  • Five selectable test voltages suit different assets and test procedures.
  • Automatic polarization index (PI) and dielectric absorption ratio (DAR) calculations.
  • Filter function reduces fluctuation in displayed readings.
  • Output and automatic-discharge voltage monitoring, with a large backlit display and bar graph.
  • A Guard terminal supports insulation tests requiring a separate surface-leakage path, as described in the manual.

Technical Specifications

Insulation test voltages250 / 500 / 1000 / 2500 / 5000 V DC
Maximum resistance range1000 GΩ at 5000 V
Voltage measurement30–600 V AC (50/60 Hz), ±30–±600 V DC
Nominal short-circuit current1.5 mA
Power8 × LR14 alkaline C batteries (1.5 V)
Dimensions177 × 226 × 100 mm
Approximate instrument weight1.9 kg including batteries
Measurement categoryCAT IV 300 V / CAT III 600 V

Package Contents

The manufacturer lists the KEW 3125A, 7165A line probe, 7264 earth lead, 7265 guard lead, 8019 hook, 9184 hard case, eight LR14 batteries and instruction manual. Check accessory part numbers against the supplied package on receipt.

Suitable Applications

For qualified maintenance personnel checking insulation on cables, motors and equipment after selecting test voltage and acceptance criteria for the asset. PI and DAR results can be recorded and compared as part of a planned inspection programme.

Important Before Purchase

This is the KEW 3125A, not the 3125B. Insulation testing applies high voltage: isolate the equipment and follow the manual's discharge and voltage-verification procedures before handling conductors. Choose test voltage from the asset's requirements rather than simply using the highest available setting.

Frequently Asked Questions

Does it support 250 V testing? Yes. Selectable DC test voltages are 250, 500, 1000, 2500 and 5000 V.

What do PI and DAR show? They compare insulation resistance at defined time intervals; interpretation depends on the asset and test procedure.

Is this the 3125B? No. This listing is for the 3125A version and its stated specifications and accessories.