BESANTEK BST-VT107 Non-Contact AC Voltage Detector, 5–1000 V
This pen-style detector helps electricians and maintenance technicians perform preliminary AC voltage checks near outlets, switches, lighting fixtures, and insulated wires. A light and an audible tone signal detection as you move between test points.
The sensitivity thumbwheel adjusts the response at the point being checked. This helps compare signals from adjacent wires or follow a signal along accessible wiring. The detector uses one AAA battery and weighs approximately 40 g with it installed.
Key Features
- Non-contact detection near insulated wiring and connection points.
- Adjustable sensitivity to suit the signal and the test point.
- Visual and audible detection alerts.
- Lightweight pen-style body for checking multiple points.
Technical Specifications
| Brand | BESANTEK |
| Model | BST-VT107 |
| Detection range | 5–1000 V AC |
| Frequency | 50–500 Hz |
| Indication | LED and audible tone |
| Power | One 1.5 V AAA battery |
| Operating temperature | 0–40°C |
| Operating humidity | Up to 80% |
| Dimensions | 142 × 28 × 27 mm |
| Weight with battery | Approx. 40 g |
Package Contents
BST-VT107 detector, one 1.5 V AAA battery, and user manual.
Suitable Applications
Preliminary voltage checks around outlets and light switches, comparing detector response near adjacent conductors, and following signals along accessible insulated wires to narrow down suspected breaks before further testing.
Important Before Purchase
For indoor use only, at altitudes up to 2,000 m and pollution degree 2. Observe the specified operating temperature and humidity limits.
The detector signals AC voltage presence. Use an appropriate multimeter for a numerical reading. Distance, cable construction, and the sensitivity setting can affect detection. Check its response on a known AC source before and after testing. Follow the approved isolation procedure and use an appropriate instrument to verify that a circuit is de-energized before maintenance. A silent detector alone cannot establish that condition.
FAQ
Will it detect a car battery? The range is for AC voltage. Use a DC-capable instrument for a car battery.
Does it display a numerical reading? It signals with light and sound. Use an appropriate multimeter to read the voltage.
When should I adjust sensitivity? Adjust it when the distance changes or when comparing adjacent wires, following the manual.
Can it trace wiring inside a wall? Use a dedicated cable locator to find a concealed cable route.
Recommended Products
- JADEVER Non Contact AC Voltage Detector — For preliminary AC voltage detection near wiring; absence of an alert does not verify that a circuit is de energized.
- Three Level AC DC Voltage Tester — For probe based voltage level checks within the tester ratings and the applicable site procedure.
- JADEVER 200 A AC Clamp Meter — For separate load current and voltage measurements during electrical troubleshooting within its ratings.
- KYORITSU KEW 3125A Insulation Tester — For insulation resistance testing at the voltage specified by the maintenance procedure, a separate function from voltage presence detection.
- WISEUP 16 Inch Tool Bag — To organize small inspection tools during transport; check internal dimensions before packing the instrument and accessories.