BESANTEK BST-ET18 Clamp-On Earth Ground Resistance Tester 30A

3795

Product description

BESANTEK BST-ET18 Clamp-On Earth Resistance and Leakage Current Tester

The BESANTEK BST-ET18 measures earth-loop resistance by clamping around an earthing conductor, without disconnecting it where the installation provides a suitable return path for this method. It also measures AC leakage current up to 30 A and stores readings for comparison during electrical inspections and maintenance.

Features

  • Earth-loop resistance and AC leakage-current measurement in one instrument.
  • A 65 × 32 mm clamp opening for conductors that fit within it.
  • Memory for up to 99 data sets and an RS232 interface for data transfer.
  • Audible and visual alarms with adjustable thresholds.
  • A four-digit LCD and automatic shutoff after approximately five minutes.
  • Interference-signal recognition as listed by the manufacturer.

Technical specifications

Earth-loop resistance0.01–1200 Ω
AC leakage current0.00 mA–30.0 A at 50 or 60 Hz
Finest published resistance resolution0.001 Ω; resolution varies with range
Finest published current resolution0.05 mA; resolution varies with range
Best published resistance accuracy±1% ±0.01 Ω; refer to the conditions for each range in the manual
Best published current accuracy±2.5% ±1 mA; refer to the conditions for each range in the manual
Clamp opening65 × 32 mm
Adjustable alarm thresholdsResistance: 1–199 Ω; current: 1–499 mA
Memory and interface99 data sets; RS232
PowerFour 1.5 V AA alkaline batteries
Operating conditions−10 to 55 °C; 10–90% relative humidity
Dimensions285 × 90 × 66 mm
Instrument weight1160 g including batteries; not the packed shipping weight

The resolution and best-accuracy figures above are the values published in the manufacturer summary. They do not necessarily apply across all ranges. Consult the operating manual for the selected range and measurement conditions before accepting a result.

Package contents

BST-ET18 tester, test ring, hard carrying case, RS232 data cable, software disc, batteries and instruction manual, per the manufacturer catalogue.

Applications

Inspect earth loops on installations suited to clamp testing, check AC leakage current and compare readings from inspection points during electrical maintenance.

Before purchase and use

A qualified technician must confirm that a suitable return path exists, check that the conductor fits the clamp and follow the manual and site procedures. Clamp-loop testing is not suitable for every earthing system or an isolated electrode without a return path. This measurement does not establish absence of voltage. Check that the RS232 cable and interface and the manufacturer software are compatible with the computer used for data transfer.

Frequently asked questions

Must the earthing conductor be disconnected?

It can remain connected where the installation supports clamp-loop testing and provides a suitable return path. A qualified technician determines whether the method is appropriate.

Does the 30 A figure refer to resistance measurement?

No. It is the maximum AC leakage-current range. The resistance range is 0.01–1200 Ω.

How many readings can be stored?

The memory holds up to 99 data sets. RS232 transfer requires a compatible interface and software.

Are resolution and accuracy the same across all ranges?

No. The summary gives the finest resolution and best published accuracy. Consult the manual for the selected range and its conditions.

What is the test ring used for?

It checks instrument response against the ring value following the manual. This functional check does not replace required periodic calibration.